• Mass Flow Controller Model 5853

    To truly control any process, you must precisely measure what is happening — in the feedline, in the chamber, at every point — then use that information in real time to keep the process precisely on-target and productive.

    As the global leader in precision fluid measurement and control, mass flow meter manufacturer Brooks Instrument continues to innovate thermal mass flow technology. From thermal flow sensors and mass flow metering systems, we continually launch new products and enhance existing systems to unlock new levels of thermal mass flow measurement precision, responsiveness, accuracy and repeatability.

    Key reasons why our mass flow sensors are the most widely used worldwide include:

    • Industry-best range of digital mass flow meters and other products to meet widest application needs
    • MultiFlo™ technology allows one device to change gas types and ranges without removing the device from the system and improving actual process gas accuracy. MultiFlo™ is offered for use with thermal thermal mass or flow sensors
    • Complete product range includes both elastomer sealed and metal sealed options for thermal mass flow sensors and coriolis mass flow sensors
    • Ultra-high purity mass flow sensors and devices engineered to satisfy thin film, semiconductor and other high-tech industry requirements
    • Datasheet

    Mass Flow Controller Model 5853

    برای قیمت تماس بگیرید
  • VEGA PULS53 Radear Level Transmitter

    Signal processing ECHOFOX® for echo analysis with Fuzzy-Logic. Adjustment via VEGACONNECT and/or PC, detachable adjustment module or HART® version via HART® handheld on 4 … 20 mA.

    Signal output:

    – Two-wire loop-powered compact sensor, also for use in Ex area, for connection to a power supply unit.

    – Four-wire compact sensor with separate power supply and current output, also for use in Ex area.

    – Sensor with digital signal transmission for connection to Profibus PA, also for use in Ex area.

    Housing of Plastic PBT or Aluminum (powder-coated)

    Process connection: flange with PTFE Coating

    Antenna system: rod antenna PTFE

    Process temperature: -40°C … +150°C

    Vessel pressure: max. 16 bar

    Measuring range: 20 m

    Protection: IP 66/IP 67

    VEGA PULS53 Radear Level Transmitter

    برای قیمت تماس بگیرید